Similar Projects
Facility Reroofing - FSU Campus Dining and Kitchen Renovation
Post-Bid
Tallahassee, FL

Belle Glade Senior Center
Post-Bid
Belle Glade, FL 33430

Roofing IDIQ
Renovation
Results
Hurlburt Field, FL 32544

Roof Replacement of Various City Wide Buildings
Results
Less than $900,000 est. value
Pembroke Pines, FL

Construction Management Services Mowat Middle School Media Center Rebuild and Reroof
Construction
Lynn Haven, FL 32444

Building 0092 Physics Re-Roof Phase 2
Post-Bid
Gainesville, FL 32610

FAMU Viticulture Re-Roofing
Results
Tallahassee, FL

Re-Roofing of North Fort Myers High School
Post-Bid
Fort Myers, FL 33903

TGK Facility Re-Roof - Pressure Wash and Seal Exterior Building
Results
Less than $3,350,000 est. value
FL

Membrane Roof Rehabilitation Deland Police Department Building
Post-Bid
Less than $100,000 est. value
De Land, FL 32720

Fire Department Reroofing Project
Results
Crystal River, FL 34428

Union Academy Upgrade-Replace Roof Building 2 (Cafeteria)
Post-Bid
Bartow, FL 33830

Eustis Fisheries Research Lab Reroof Project
Results
Less than $187,000 est. value
Eustis, FL

Emergency Hurricane Roof Repair Tyndall Elementary School
Post-Bid
Panama City, FL 32400

Hardening and Retrofitting of the City Hall
Results
Less than $340,000 est. value
Tavares, FL

Reported 08/17/2020 12:00 AM
Project Title

Roof Repair Replacement - Key West FL

Physical Address View project details and contacts
City, State (County) Key West, FL 33040   (Monroe County)
Category(s) Single Trades
Sub-Category(s) Roofing
Contracting Method Competitive Bids.
Project Status Request for Quotations
Bids Due View project details and contacts
Estimated Value Less than $25,000
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Deliver the following to NOAA ONMS Key West National Marine Sanctuary: • Remove existing roof membrane (approximately - 300 square feet). • Remove existing roof flashing (approximately - 80 linear feet). • Replace any roof decking deemed to be failed (up to 300 square feet). • Haul away any roofing parts removed. • Install approximately 300 sf of standard EPDM roof membrane underlayment (30 mils or greater). • Install up to 300 sf of corrugated metal roof deck (26 gauge or higher). • Install approximately 80 lf of roof flashing.

Details

Division 07 - Thermal and Moisture Protection, Dampproofing and Waterproofing, Thermal Protection.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents