Reported | 03/03/2022 12:00 AM |
Project Title | Saints Hall HVAC Units |
Physical Address | View project details and contacts |
City, State (County) | Andalusia, AL (Covington County) |
Category(s) | Single Trades |
Sub-Category(s) | HVAC |
Contracting Method | Competitive Bids. |
Project Status | Bidding |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | State Agency |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | 1. Installation of (16) 2-ton Carrier 14 SEER split system heat pumps with strip heaters 2. Installation of a Honeywell T6 digital thermostat for 11 of the systems and Honeywell Vision Pro 8000 3 Heat/2 Cool staging thermostats with RedLink technology and remote module for 5 of the systems. 3. Each system will need a filter base installed and a drain safety switch. 4. The existing hydronic heat water systems will need to be capped off. |
||
Details |
|
||
Bidder's List | View project details and contacts | ||
Prospective Bidders | View project details and contacts | ||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |