Similar Projects
Last Updated | 04/16/2021 03:12 PM |
Project Title | Utility Relocation in Advance of the TxDOT FM 455 Improvements |
Physical Address | View project details and contacts |
City, State (County) | TX (Denton County) |
Category(s) | Sewer and Water |
Sub-Category(s) | Water Lines |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | $2,661,000 |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | 11,033 LF of 12" Dia. PVC (DR 18) constructed via open cut (OC) and 435 LF of PVC Water Carrier Pipe (DR18) will be inserted in 18-Inch Steel Casing Pipe constructed via OC and 231 LF of 18-inch Steel Casing constructerd 8via Other Than Open Cut (OTOC), 177 LF of 8-inch dia. PVC (DR18) constructed via OC and 363 L.F. 11,033 LF of 12" dia. PVC (DR 18) constructed via Open Cut (OC) and 435LF PVC Water Carrier Pipe (DR 18) will be inserted in 18" Steel Casing, 204LF of 18" Steel Casing pipe constructed via OC and 231LF of 18" Steel Casing constructed via Other Than Open Cut (OTOC), 177LF of 8" dia. PVC (DR 18) constructed via OC and 363LF of 8" PVC Water Carrier Pipe (DR18) inserted in 12" Steel Casing, 1,029LF of 12" Steel Casing Pipe by OC, 405LF of 1211 Steel Casing by OTOC, 1,261LF of 6" dia. PVC (DR 18) constructed via OC and 1,084LF of 6" PVC Water Carrier Pipe (DR18) inserted in a 12" Steel Casing, 176LF of 4" and 2" PVC constructed via OC, 11 -12" resilient seat gate valves, 4- 8" resilient seat gate valves, 13 - 6" resilient seat gate valves, 6 -flush hydrants, 2- fire hydrants C502-85, 30 - Water Service Reconnections, 21 - Water Meter Box Relocations , Various Ductile Iron Tees, Bends, Fittings and Related Appurtenances. 1,029LF of 12" Steel Casing Pipe by OC, 405LF of 1211 Steel Casing by OTOC, 1,261LF of 6" dia. PVC (DR 18) constructed via OC and 1,084LF of 6" PVC Water Carrier Pipe (DR18) inserted in a 12" Steel Casing, 176LF of 4" and 2" PVC constructed via OC, 11 -12" resilient seat gate valves, 4- 8" resilient seat gate valves, 13 - 6" resilient seat gate valves, 6 -flush hydrants, 2- fire hydrants C502-85, 30 - Water Service Reconnections, 21 - Water Meter Box Relocations , Various Ductile Iron Tees, Bends, Fittings and Related Appurtenances. |
||
Details |
|
||
Bidder's List | View project details and contacts | ||
Prospective Bidders | View project details and contacts | ||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |