Similar Projects
Last Updated | 12/31/2020 02:31 PM |
Project Title | Sanding Booth |
Physical Address | View project details and contacts |
City, State (County) | Coraopolis, PA 15108 (Allegheny County) |
Category(s) | Single Trades |
Sub-Category(s) | Equipment |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | CLIN 001) Industrial Sanding Booth capable of collecting dust created when sanding aircraft and other parts with Hexivalent chrome primer. Salient Characteristics are as follows: --99.9% Filter Efficiency --Approx 2,700 Sq Ft of Filter Area --Motor shall be or perform at a level equal to that of a 10HP, 460v., 3ph., 1750rpm, 12.4FLA, TEFC motor. Direct drive, airfoil design, non-overloading blower (MV24-87%FB or equal). Air volume: 10,000 CFM or greater. --Variable frequency drive for "soft startup" and reduced suction during cleaning cycle. NEMA 4X with heat sink for cooling of VFD. --Electrical control box to front, outside booth. Solenoid valves in seperate box. Both easily accessible by operator. --Magnehelic or better gauge for filter status. --Welded heavy gauge carbon steel or better construction. --Booth structure shall be made of unpainted galvanized steel or better material with minimum 2" fiberglass insulation compressed and covered by a minimum .5 MIL thick white vinyl, regain airsystem, with at least (6) 4' x 2 lamp sealed fluorescent light fixtures located inside. --DURA-PLATE 239 multi-purpose epoxy coating or better throughout dust collector and regain air plenum. --Electrical Hookup Requirements: (1) 460V 3PH 60hz; MCA: 18A; (1) 120V 1PH. --Entire unit must fit inside a room measuring approx. 12' Wx 16' 4" D x 8' 11" T. --High temperature cut-off switch for fire protection. --Nano fiber or better, flame-retardant filtration cartridges or similar. --Must be able to self-clean through Reverse Pulse Jet process or similar with PLC control of pulse cleaning sequence; must also have auto off-line and programmable Compressed air regulator and filter capabilities. --Minimum of 3 standard fire sprinkler connections. --1 Year warranty on parts at minimum. All quotes shall include pricing for freight, labor, and all other pricing as it relates to installing the system. All permits, connections, necessary for setup currently exist. |
||
Details |
|
||
Bidder's List | View project details and contacts | ||
Prospective Bidders | View project details and contacts | ||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |