Reported | 03/27/2020 09:34 AM |
Project Title | William East Dandy Middle School-Smart Program Renovations |
Physical Address | View project details and contacts |
City, State (County) | Fort Lauderdale, FL 33311 (Broward County) |
Category(s) | Education |
Sub-Category(s) | Middle/Senior High School |
Contracting Method | Competitive Bids. |
Project Status | Sub-Bidding |
Bids Due | View project details and contacts |
Estimated Value | $2,101,196 |
Plans Available from | General Contractor |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | • Replace the entire fire alarm system and provide missing exit signs. • Repairs to the existing aluminum covered walkways. Building 1 (Administration): Reroofing; replace air handling unit in Mechanical Room 120. Building 2: Reroofing and HVAC Equipment replacement. Building 3: Reroofing. Building 4: Reroofing and chillers replacement. Building 5: Reroofing and install missing exit signs. Building 6: Reroofing and install missing exit signs. Building 7: Reroofing and install missing exit signs. Building 8: Reroofing and install missing exit signs. Building 9: Reroofing and install missing exit signs. Building 10: Reroofing and install missing exit signs. Building 11: Reroofing and install missing exit signs. Building 12 (Group Restroom): Reroofing. Building 13 (Group Restroom): Reroofing. Building 14 (Group Restroom): Reroofing; painting of exterior soffit Building 15 (Group Restroom): Reroofing. Building 16 (Media Center): Reroofing. Building 17 (Group Restroom): Reroofing, painting of exterior soffit. Building 18 (Group Restroom): Reroofing; renovation of Female Student Restroom 311. Building 19 (School Health Center): Reroofing and install missing exit signs. Included in the Reroofing: • Provide new modified bitumen built-up roofing over existing '/.." per footsloped light weight insulated concrete. (Existing insulation value is approximately R-20 based on record drawings). • Remove abandonE9d rooftop equipment and unneeded close-up openings inthe roof deck, if any. • Correct current deficiencies in roof drainage. • Replace horizontal and vertical roofing expansion joints. • Upon removal of the existing roofing membrane, inspect the roof deck.Where found damaged or deteriorated, replace all such areas of the roof decking. • Relocate rooftop equipment currently located closer than 10 feet to the roofedge, or provide railings at the roof edge (as required by the Florida BuildingCode). • Raise the stands for rooftop equipment to provide a minimum of 24-inch clearance from the bottom of the supports to the new finished roofing surface(if and where such clearance would not be provided after the installation of the new insulation/roofing system). Where shown in drawings, provide new curbs for stand and curb-mounted rooftop equipment in order to provide a minimum height of 18 inches from the new finished roofing surface to the top of the curb. Provide hurricane tie-down straps at rooftop equipment if and where missing. • Raise existing plumbing vents as required to provide proper flashing. • Plumbing vents close to parapet walls shall be rerouted away from the parapet. • Reinforce the roof structure |
||||||||||||||||||
Details |
|
||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |