Similar Projects
CRA Project - Phase 2 Seawall and Retaining Wall Replacement
Bidding
Jacksonville, FL 32207

Arrow and Message Boards
Term Contract
Post-Bid

Arrow and Message Boards
Term Contract
Post-Bid

Apply High Density Mineral Bond
Results
Less than $90,000 est. value
FL

Property Directional Signs (3 Properties)
Results
Jacksonville, FL

Flexible Delineator Post
Term Contract
Post-Bid

District-Wide Thermopalstic Contract
Results
Less than $750,000 est. value

SERMC Port Security Barriers Services
Post-Bid
Jacksonville, FL 32227

Drainage
Results
Less than $696,612 est. value
FL

Traffic Cones
Term Contract
Results

Flight Line Restriping, Army Aviation Support Facility (AASF) #1
Results
Less than $95,500 est. value
Jacksonville, FL 32211

Roadway Signing
Results
Less than $1,935,615 est. value

Barricade Rental for TIAA Stadium Activities
Term Contract
Results
Less than $85,000 est. value
Jacksonville, FL 32202

Hot Asphalt Speed Hump & Speed Table Construction Countywide
Results
Less than $250,000 est. value
Jacksonville, FL 32099

Traffic Signs Unit Price Construction Countywide
Results
Less than $200,000 est. value
Jacksonville, FL

Last Updated 06/04/2020 03:42 PM
Project Title

Emergency Sign Repair and Replacement

Physical Address View project details and contacts
City, State (County) (Clay, Duval, Nassau, Putnam, Saint Johns Counties)
Category(s) Heavy and Highway
Sub-Category(s) Highway Signs/Guardrails/Barriers
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Eastern Regional Contract to provide Sign Repair and Replacement Operations pursuant to a Governor's and/or President's Declaration of a State Emergency. This Contract will be a regional contract that includes Clay, Duval, Nassau, Putnam, and St. Johns Counties within District 2. Section 0001 Emer.Delineator/Attenuator/Sign Repr(Ea) 0630- 2- 11 Conduit, Furnish & Install, Open Trench Lf 1.000 0630- 2- 12 Conduit, Furnish & Install, Directional Bore Lf 1.000 0630- 2- 14 Conduit, Furnish & Install, Aboveground Lf 1.000 0630- 2- 15 Conduit, Furnish & Install, Bridge Mount Lf 1.000 0632- 7- 2 Signal Cable- Repair/Replace/Other, Furnish & Install Lf 1.000 0634- 4-142 Span Wire Assembly, f&i, Single Point, Diagonal Pi 1.000 0634- 4-152 Span Wire Assembly, f&i, Two Point, Diagonal Pi 1.000 0635- 2- 11 Pull & Splice Box, f&i, 13" x 24" Cover Size Ea 1.000 0635- 2- 12 Pull & Splice Box, f&i, 24" x 36" Cover Size Ea 1.000 0639- 1-111 Electrical Power Service, f&i, Overhead, Meter Furnished By Power Company As 1.000 0639- 1-112 Electrical Power Service, f&i, Overhead Meter Purchased By Contractor From Power Company As 1.000 0639- 1-113 Electrical Power Service, f&i, Overhead Meter Not Required As 1.000 0639- 1-121 Electrical Power Service, f&i, Underground, Meter Furnished By Power Company As 1.000 0639- 1-122 Electrical Power Service, f&i, Underground, Meter Purchased By Contractor As 1.000 0639- 1-123 Electrical Power Service, f&i, Underground, Meter Not Required As 1.000 0641- 2- 12 Prestressed Concrete Pole, f&i, Type p-Ii Service Pole Ea 1.000 0641- 2- 15 Prestressed Concrete Pole, f&i, Type p-v Ea 1.000 0670- 4- 1 Intersection Control Beacon Controller Assembly, Furnish & Install As 1.000 0700- 1- 11 Single Post Sign, f&i Ground Mount, Up To 12 Sf As 1.000 0700- 1- 12 Single Post Sign, f&i Ground Mount, 12-20 Sf As 1.000 0700- 1- 13 Single Post Sign, f&i Ground Mount, 21-30 Sf As 1.000 0700- 1- 14 Single Post Sign, f&i Ground Mount, 31+ Sf As 1.000 0700- 1- 21 Single Post Sign, f&i Barrier Mount Index 11871/700-013 Up To 12 Sf As 1.000 0700- 1- 22 Single Post Sign, f&i Barrier Mount Index 11871/700-013, 12-20 Sf As 1.000 0700- 1- 31 Single Post Sign, f&i Bridge Mount Index 11870/700-012, Up To 12 Sf As 1.000 0700- 1- 32 Single Post Sign, f&i Bridge Mount Index 11870/700-012, 12-20 Sf As 1.000 0700- 1- 80 Single Post Sign, Repair As 1.000 0700- 1- 87 Single Post Sign, Repair- Replace Post, Use Existing Sign Panel As 1.000 0700- 2- 11 Multi- Post Sign, f&i Ground Mount, Up To 12 Sf As 1.000 0700- 2- 12 Multi- Post Sign, f&i Ground Mount, 12-20 Sf As 1.000 0700- 2- 13 Multi- Post Sign, f&i Ground Mount, 21-30 Sf As 1.000 0700- 2- 14 Multi- Post Sign, f&i Ground Mount, 31-50 Sf As 1.000 0700- 2- 15 Multi- Post Sign, f&i Ground Mount, 51-100 Sf As 1.000 0700- 2- 16 Multi- Post Sign, f&i Ground Mount, 101-200 Sf As 1.000 0700- 2- 17 Multi- Post Sign, f&i Ground Mount, 201-300 Sf As 1.000 0700- 2- 18 Multi- Post Sign, f&i Ground Mount, 301-400 Sf As 1.000 0700- 2- 50 Multi- Post Sign, Ground Mount, Relocate As 1.000 0700- 3-101 Sign Panel, Furnish & Install Ground Mount, Up To 12 Sf Ea 1.000 0700- 3-102 Sign Panel, Furnish & Install Ground Mount, 12-20 Sf Ea 1.000 0700- 3-103 Sign Panel, Furnish & Install Ground Mount, 21-30 Sf Ea 1.000 0700- 3-104 Sign Panel, Furnish & Install Ground Mount, 31-50 Sf Ea 1.000 0700- 3-105 Sign Panel, Furnish & Install Ground Mount, 51-100 Sf Ea 1.000 0700- 3-106 Sign Panel, Furnish & Install Ground Mount, 101-200 Sf Ea 1.000 0700- 3-107 Sign Panel, Furnish & Install Ground Mount, 201-300 Sf Ea 1.000 0700- 3-108 Sign Panel, Furnish & Install Ground Mount, 301-400 Sf Ea 1.000 0700- 3-109 Sign Panel, Furnish & Install Ground Mount, 401-500 Sf Ea 1.000 0700- 3-201 Sign Panel, Furnish & Install Overhead Mount, Up To 12 Sf Ea 1.000 0700- 3-202 Sign Panel, Furnish & Install Overhead Mount, 12-20 Sf Ea 1.000 0700- 3-203 Sign Panel, Furnish & Install Overhead Mount, 21-30 Sf Ea 1.000 0700- 3-204 Sign Panel, Furnish & Install Overhead Mount, 31-50 Sf Ea 1.000 0700- 3-205 Sign Panel, Furnish & Install Overhead Mount, 51-100 Sf Ea 1.000 0700- 3-206 Sign Panel, Furnish & Install Overhead Mount, 101-200 Sf Ea 1.000 0700- 3-207 Sign Panel, Furnish & Install Overhead Mount, 201-300 Sf Ea 1.000 0700- 3-208 Sign Panel, Furnish & Install Overhead Mount, 301-400 Sf Ea 1.000 0700- 3-209 Sign Panel, Furnish & Install Overhead Mount, 401-500 Sf Ea 1.000 0700- 3-210 Sign Panel, Furnish & Install Overhead Mount, 501-600 Sf Ea 1.000 0700- 3-211 Sign Panel, Furnish & Install Overhead Mount, 601 Sf And Greater Ea 1.000 0700- 3-301 Sign Panel, Furnish & Install Single Post Bridge Mount Index 11870/700-012, Up To 12 Sf Ea 1.000 0700- 3-302 Sign Panel, Furnish & Install Single Post Bridge Mount Index 11870/700-012, 12-20 Sf Ea 1.000 0700- 3-401 Sign Panel, Install, Up To 12 Sf Ea 1.000 0700- 3-402 Sign Panel, Install, 12-20 Sf Ea 1.000 0700- 3-403 Sign Panel, Install, 21-30 Sf Ea 1.000 0700- 3-404 Sign Panel, Install, 31-50 Sf Ea 1.000 0700- 3-405 Sign Panel, Install, 51-100 Sf Ea 1.000 0700- 3-406 Sign Panel, Install, 101-200 Sf Ea 1.000 0700- 3-407 Sign Panel, Install, 201-300 Sf Ea 1.000 0700- 3-408 Sign Panel, Install, 301-400 Sf Ea 1.000 0700- 4-111 Overhead Static Sign Structure, Furnish & Install, Cantilever, Up To 20 Ft Ea 1.000 0700- 4-112 Overhead Static Sign Structure, Furnish & Install, Cantilever, 21-30 Ft Ea 1.000 0700- 4-113 Overhead Static Sign Structure, Furnish & Install, Cantilever, 31-40 Ft Ea 1.000 0700- 4-114 Overhead Static Sign Structure, Furnish & Install,Cantilever, 41-50 Ft Ea 1.000 0700- 4-121 Overhead Static Sign Structure, Furnish & Install, Span, Up To 20 Ft Ea 1.000 0700- 4-122 Overhead Static Sign Structure, Furnish & Install, Span, 21-30 Ft Ea 1.000 0700- 5- 11 Internally Illuminated Sign, Furnish & Install Ground Mount, Up To 12 Sf Ea 1.000 0700- 5- 21 Internally Illuminated Sign, Furnish & Install Overhead Mount, Up To 12 Sf Ea 1.000 0700- 5- 22 Internally Illuminated Sign, Furnish & Install, Overhead Mount, 12-18 Sf Ea 1.000 0700- 11-121 Electronic Display Sign, Furnish & Install Ground Mountac Powered, Electronic Regulatory Sign, Up To 12 Sf As 1.000 0700- 11-321 Electronic Display Sign, Furnish & Install Overhead Mount- Ac Powered, Regulatory Sign, Up To 12 Sf As 1.000 0700- 12- 11 Sign Beacon, f&i Ground Mount- Ac Powered, One Beacon As 1.000 0700- 12- 12 Sign Beacon, f&i Ground Mount- Ac Powered, Two Beacon As 1.000 0700- 12- 21 Sign Beacon, f&i Ground Mount- Solar Powered, One Beacon As 1.000 0700- 12- 22 Sign Beacon, f&i Ground Mount- Solar Powered, Two Beacons As 1.000 0700- 12- 31 Sign Beacon, f&i Overhead Mount, One Beacon As 1.000 0700- 12- 32 Sign Beacon, f&i Overhead Mount, Two Beacons As 1.000 0700- 12- 60 Sign Beacon, Remove Beacon- Sign To Remain As 1.000 0705- 10- 1 Object Marker, Type 1 Ea 1.000 0705- 10- 2 Object Marker, Type 2 Ea 1.000 0705- 10- 3 Object Marker, Type 3 Ea 1.000 0705- 11- 1 Delineator, Flexible Tubular Ea 1.000 0705- 11- 2 Delineator, Non-Flexible Ea 1.000 0705- 11- 3 Delineator, Flexible High Visibility Median Ea 1.000 0705- 11- 4 Delineator, Flexible High Performance 48" Ea 1.000 e700- 46- 32 Repair Existing Sign (Multi Post) As 1.000

Details

Division 10 - Specialties, Signage.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents