Similar Projects
Replace Five Existing Interior Chilled Water Air Handling Units
Alteration
Bidding
$1,618,750 est. value
Dartmouth, MA

Mclean Campus Center HVAC Upgrade - General
Alteration
Bidding
$1,618,750 est. value
Dartmouth, MA 02747

Renovation of Lobby and Security Upgrades - Corrigan MHC Sub-Bid
Post-Bid
Less than $295,000 est. value
Fall River, MA 02720

On-Call, Routine and Emergency Heating System
Term Contract
Post-Bid
Less than $98,000 est. value
New Bedford, MA

HVAC System Replacement at the District 5 Administration Building
Results
Less than $380,000 est. value
Taunton, MA 02718

Dottin Place Administration Building HVAC Systems Upgrade Project
Results
$145,000 est. value
New Bedford, MA 02745

HVAC Maintenance & Repairs
Term Contract
Bidding
Hyannis, New Bedford, MA - Middletown, Providence, RI 02908

Replacement of Rooftop Unit
Post-Bid
Less than $150,000 est. value
New Bedford, MA

Brickenwood Administration Offices New HVAC Project
Results
Less than $50,000 est. value
New Bedford, MA 02746

Air Vent Cleaning of Aviation Hangars
Post-Bid

Furnace and Domestic Water Heater Replacement - Sub Bid
Results
Less than $235,000 est. value
New Bedford, MA 02745

HVAC and Mechanical Products
Term Contract
Post-Bid

Furnace and Domestic Water Heater Replacement - General Bid
Results
$235,000 est. value
New Bedford, MA 02745

Ford Middle School Evaporators and Condensers Replacement
Post-Bid
Acushnet, MA 02743

Removal of Existing Bathroom Exhaust Fans and Installation of New Bathroom Exhaust Fans and All Necessary Components
Results
$50,000 est. value
New Bedford, MA

Last Updated 03/09/2022 10:54 AM
Project Title

McLean Campus Center HVAC Upgrade - Filed Sub Bids

Physical Address View project details and contacts
City, State (County) Dartmouth, MA 02747   (Bristol County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $1,618,750
Plans Available from Copy Center
Owner View project details and contacts
Architect View project details and contacts
Description

DCAMM Certification. Replacement of 5 existing indoor chilled water AHUs, associated inline return fans and chilled water recirc. pumps. All duct-mounted re-heat coils associated with these AHUs shall be replaced with VAV boxes including hot water re-heat coils. All scope area zone temperature sensors are being replaced with new sensors, and densely occupied areas are being provided with new CO2 sensors to allow for demand control ventilation. All AHU and Return fans shall be speed-controlled with modulating VFDs.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.
Division 26 - Electrical.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents