Similar Projects
Last Updated | 07/24/2020 12:46 PM |
Project Title | NED SHIP Housing Repair for 803 Massachusetts Avenue |
Physical Address | View project details and contacts |
City, State (County) | Pensacola, FL 32505 (Escambia County) |
Category(s) | Residential |
Sub-Category(s) | Single-Family Homes |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | $33,620 |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Remove existing roof covering to the decking and replace any deteriorated or damaged decking with like, kind and quality of existing materials (figure 228 Square feet.). Fasten and certify decking attachment as per Escambia County Building Code. Replace deteriorated rafters, approximately 60 lineal foot. Install 30 year shingle roof on roof areas with a 3/12 pitch or better as per manufacturer’s specifications with secondary water barrier as per Escambia County Building Code. Install self-adhering granulated modified bitumen roll roofing on low pitch areas with manufacturers recommended secondary water barrier as per manufacturer specifications. Replace existing drip edge with new metal drip edge. Install new slant-back vents. Replace all boots with new lead or EPDM and metal boots. Trim trees over hanging roof to clear roof by approximately 10’. Remove tree trimming debris from premises. Replace 22 lineal feet of seamless gutter on rear elevation with leaf guard using existing down pipe Install drywall on ceiling and finish to paint. Replace front entry door unit with metal clad hurricane rated insulated 6 panel colonial door unit with threshold, weather stripping, peep hole and trim. Install new storm door at front entrance matching existing as close as possible with like, kind and quality. Replace out swing door unit on storage room with metal clad hurricane rated insulated 6 panel colonial door unit with threshold, on rot jambs, weather stripping and trim. Install new dead bolt and lock sets that are keyed alike on all new exterior door units. Paint new door units inside and out to match existing as close as possible. Rescreen patio door with like, kind and quality of screening material. Electrical Plumbing Interior Walls Interior Ceiling |
||||||||||||||||||||||||||||||||
Details |
|
||||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |