Similar Projects
Electrician
Alteration
Bidding
Rutland, VT

Household Hazardous Waste and Conditionally Exempt Generator Collections 2022-2023
Term Contract, Alteration
Bidding
Montpelier, VT

Town and Community Solar PV Project
Post-Bid
Hinesburg, VT

Generator Replacement - Castleton Elementary School
Post-Bid
Bomoseen, VT 05732

NSL Replace the Electrical Conduits
Results
$250,000 to $500,000 est. value
Springfield, VT

Z--Tiered Evaluation Pre-Solicitation Notice White River Junction Replace Underground Utilities Construction Project
Results
$5,000,000 to $10,000,000 est. value
White River Jct, White River Junction, VT 05009

Lyndon Town School Generator Power System
Post-Bid
Lyndon, VT

EV Charging Station
Results
Richmond, VT 05477

2020 Emergency Generator Project
Post-Bid
Norwich, VT

Town Garage Generator Connection
Results
$7,860 est. value
Londonderry, VT

Repair/Upgrade Base Electrical Distribution System - Vermont Air National Guard Base
Post-Bid
$1,000,000 to $5,000,000 est. value
South Burlington, VT

EAFR Cantonment Loop Energy Resilency
Results
Jericho, VT

On-Call Electrical and Controls Services
Term Contract
Post-Bid
Burlington, VT

EAFR Northside/Southside Energy Resiliency
Results
Jericho, VT

Umbrella Contracts for Statewide Electrical Services
Post-Bid
Montpelier, VT

Last Updated 10/20/2021 11:55 AM
Project Title

J061--Emergency Power Equipment PM Asco Automatic Transfer Switches

Physical Address View project details and contacts
City, State (County) Hartford, VT 05009   (Windsor County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

A. General Information 1. Title of Project: Annual Automatic Transfer Switch maintenance 2. Scope of Work: Perform an Annual Maintenance on (28) ASCO Automatic Transfer Switches. B. Automatic Transfer Switches 1. This work must be completed by a ASCO trained and certified technician 2. De-energize the ATS. 3. Remove the arc shuts, pole covers and perform visual inspection of the main and arching contacts. 4. Test and recalibrate all trip-sensing and time-delay functions in the ATS. 5. Vacuum the accumulated dust from the ATS and accessory panels. Do not use compressed air. 6. Inspect for signs of moisture or signs of previous wetness or dripping. 7. Clean grime with an approved solvent (consult the OEM for approved solvent). 8. Inspect all insulating parts for cracks or discoloration due to excessive heat. 9. Inspect all main arcing contacts for erosion. 10. Inspect all main current-carrying contacts for pitting and discoloration due to excessive heat. 11. Inspect all control relay contacts for excessive erosion and discoloration due to excessive heat. 12. Manually operate the main transfer movement to check for proper contact alignment, deflection, gap and wiping action. 13. Check all cable and control wire connections and tighten if necessary.

Details

Division 26 - Electrical, Transfer Switches, Automatic Transfer Switches.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents