Similar Projects
HVAC Services- DMV Norfolk-Widgeon Road CSC
Post-Bid
Chesapeake, Norfolk, VA 23513

HVAC and Mechanical Products
Term Contract
Post-Bid

Roof Top Air Handling Unit
Results
Chesapeake, VA 23323

HVAC System Replacement at the Landstown Transfer Station
Results
Chesapeake, VA 23320

Air Purification Systems
Post-Bid
Chatham, Pound, Victoria, VA 23936

HVAC Preventative Maintenance and Emergency Service
Term Contract
Results
Chesapeake, Norfolk, Portsmouth, Suffolk, Virginia Beach, VA

HVAC Maintenance and Repair
Post-Bid
Chesapeake, Portsmouth, VA 23322

Commercial HVAC Equipment and Technical Services
Results
$156,270 est. value
Chesapeake, VA

Armstrong SF665DW Heater Replacement Parts
Post-Bid

Packaged Rooftop Unit Replacement - Portlock Primary School
Results
Chesapeake, VA

Packaged Rooftop Unit Replacement - Hickory Middle School and Hugo A. Owens Middle School
Results
Chesapeake, VA 23322

Maintenance and Repair Services on HVAC Direct Digital Control Systems
Term Contract
Results
Chesapeake, Norfolk, Portsmouth, Suffolk, Virginia Beach, VA 23320

Packaged Rooftop Unit Replacement - Edwards-Wilson Center
Term Contract
Results
Chesapeake, VA 23324

Cooling Tower Replacement - Indian River Middle School
Results
$118,370 est. value
Chesapeake, VA 23322

Rooftop Unit, RTVAV-8 HVAC Replacement - Greenbrier Middle School
Results
Chesapeake, VA

Last Updated 09/30/2020 12:11 PM
Project Title

HVAC Replacement - Portlock Primary School Media Center

Physical Address View project details and contacts
City, State (County) Chesapeake, VA   (Chesapeake City County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from Engineer - 08/31/20
Owner View project details and contacts
Architect View project details and contacts
Description

Demolition 1. Remove (2) existing, split system HVAC equipment serving the media center. 2. Disconnect supply and return ductwork connections and duct mounted smoke detectors. 3. Remove condensate drain, refrigerant piping, etc. 4. Remove existing electrical power feed, as required. 5. Disconnect Controls from units. New Work: 1. Install (2) package rooftop units of equal capacity to the system removed. New units to be roof mounted, gas heat, electric cool, units mounted on curbs. 2. Install new electrical power feeds as required. 3. Install new natural gas, condensate drain piping to nearest roof drain. 4. Reconnect unit to existing supply and return duct, provide new duct smoke detectors. 5. New Automatic Temperature Controls to be “stand alone” for connection to future DDC System. 6. Provide for miscellaneous structural support on roof to accommodate new HVAC unit.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents