Similar Projects
Reported | 07/01/2021 11:07 AM |
Project Title | Polk Information Systems Facility |
Physical Address | View project details and contacts |
City, State (County) | Fort Polk, LA (Vernon County) |
Category(s) | Commercial |
Sub-Category(s) | Communication Building |
Contracting Method | Design-Build. Competitive Bids. |
Project Status | Pre-Solicitation |
Bids Due | View project details and contacts |
Estimated Value | $20,000,000 to $50,000,000 |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | The Government is seeking qualified, experienced sources capable of constructing a standard design Information Systems Facility. Project includes an information system processing area divided into specified security zones that address special use space for a Data Center, Network Operations Center (NOC), Local Session Controller Node (LSCN), and administration and warehousing. Construction includes redundant mechanical and electrical systems with backup power, secure organizational vehicle parking, loading/service areas, fire protection and alarm systems, Intrusion Detection System (IDS) installation, and Utility Monitoring Control Systems (UMCS) connection. Adherence to TEMPEST security standards will be provided. Low Impact Development Integrated Management Practices (LID-IMPs) and sustainability and energy enhancement measures are included. Supporting facilities include site development, utilities and connections, lighting, paving, parking, walks, curbs and gutters, storm drainage, landscaping, and signage. Heating and air conditioning will be provided by connection to a self-contained system. Measures in accordance with the Department of Defense (DoD) Minimum Antiterrorism for Buildings standards will be provided. Comprehensive building and furnishings related interior design services are required. Facilities will be designed to a minimum life of 40 years in accordance with DoD's Unified Facilities Code (UFC 1-200-02) including energy efficiencies, building envelope and integrated building systems performance. Access for individuals with disabilities will be provided. Cooling is estimated at 128 tons for the administrative and support areas, 232 tons for the Data Center, and 245 tons for redundant mechanical systems. |
||||||||||||||||||||||||||||||||||||
Details | Communication Building, New Construction.
|
||||||||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |